Holot Water Tower Preservation

PRODUCTS
MCI®-2020

PROBLEM
The 40 year old water tower developed cracking due to corrosion
and leaks necessitating repair.

APPLICATION
First, all delaminated, unstable concrete was removed. Exposed reinforcing
steel was cleaned and new concrete patches were placed. The
entire structure was then treated with two coats of MCI®-2020…

להמשך קריאה

פורסם במקור ב- http://www.corteccasehistories.com

Sharira Water Tower Preservation

PRODUCTS
MCI®-2020

PROBLEM
This is a second phase of repairs to a 40 year old water tower. This
tower developed cracking due to corrosion and leaks necessitating
repair.

APPLICATION
First, all delaminated, unstable concrete was removed. Exposed reinforcing
steel was cleaned and new concrete patches were placed.
The entire structure was then treated with two coats of MCI®-2020…

להמשך קריאה

פורסם במקור ב- http://www.corteccasehistories.com

South Water Tower Preservation

PRODUCTS
MCI®-2020

PROBLEM
This 25 year old water tower developed corrosion cracking, spalling
and water leaks necessitating repair.

APPLICATION
First, all delaminated, unstable concrete was removed. Exposed reinforcing
steel was cleaned and new concrete patches were placed.
The entire structure was then treated with two coats of MCI®-2020…

להמשך קריאה

פורסם במקור ב- http://www.corteccasehistories.com

BRANDEIS Water Tower Preservation

PRODUCTS
MCI®-2020

PROBLEM
This 70 year old water tower developed corrosion cracking, spalling
and water leaks necessitating repair.

APPLICATION
First, all delaminated, unstable concrete was removed. Exposed reinforcing
steel was cleaned and new concrete patches were placed.
The entire structure was then treated with two coats of MCI®-2020…

להמשך קריאה

פורסם במקור ב- http://www.corteccasehistories.com

North Water Tower Preservation

PRODUCTS
MCI®-2020

PROBLEM
This 50 year old water tower developed corrosion cracking, spalling
and water leaks necessitating repair.

APPLICATION
First, all delaminated, unstable concrete was removed. Exposed reinforcing
steel was cleaned and new concrete patches were placed.
The entire structure was then treated with two coats of MCI®-2020…

להמשך קריאה

פורסם במקור ב- http://www.corteccasehistories.com

Stav Street Residential Building Restoration

PRODUCTS
MCI®-2020 Gel

PROBLEM
Stone cladding tiles began detaching and falling off
a residential building only five years after its construction. The
cause of the damage was diagnosed as corrosion of the building’s
concrete reinforcement and cladding anchors. After seven years
of legal litigation (12 years from construction), it was ruled that
restoration should include drilling and injection of MCI®-2020 Gel
corrosion inhibitors.

להמשך קריאה

פורסם במקור ב- http://www.corteccasehistories.com

Restoration of Ben-Gurion Street Residential Building

PROBLEM
Stone cladding tiles began detaching and falling off a residential
building only 15 years after construction. An initial repair done
to re-anchor the tiles was conducted without MCI®. In the following
years, tiles continued to fall, and exposed concrete began to
delaminate. The cause of the damage was identified as corrosion
of the building’s concrete reinforcement and cladding anchors. As
the rebar corroded it expanded, pushing out on the tiles and making
them wobble. A second repair was in order only 25 years after
construction following an expensive and ineffective first repair.

APPLICATION
The second repair plan included the application of MCI® (Migrating
Corrosion Inhibitors)…

להמשך קריאה

פורסם במקור ב- http://www.corteccasehistories.com

Restoration of Concrete Foundations at Carmel Olefins

PRODUCTS
MCI®-2006 NS
MCI®-2020
MCI® Tablets (Cor-Pak® Tablets)

PROBLEM
Dozens of cubic meters of concrete foundations that
support heavy equipment in a polyethylene/polypropylene
plant had suffered significant corrosion damage.
This is common in aggressive environments saturated
with chemicals. Embedded rebar had corroded and expanded,
causing the concrete to crack and delaminate in
many areas. Renovation required a long-term perspective
without stopping the plant’s production.

APPLICATION
The chosen solution addressed three aspects of concrete
preservation.

להמשך קריאה

פורסם במקור ב- http://www.corteccasehistories.com

Extending Service Life: Sorek Desalination Plant

PROBLEM
Currently, Sorek is the largest reverse-osmosis desalination
plant worldwide. As an infrastructure facility built on the
seashore and designed to process seawater, longevity of the
plant’s concrete was a major concern. Construction plans included
the use of prefabricated concrete jack-pipe segments
(comprising the longest single-push concrete jack-pipe to date:
2.6 m [8.5 ft] ID, 1500 m [4921 ft]), concrete pretreatment sand
filtration bins, and concrete brine water reservoirs.

APPLICATION
Because of the aggressive environment, initial plans were to include
MCI® in all concrete components to protect the rebar reinforcement
and ensure continued service life for the planned
duration.

להמשך קריאה